Ground & Drone Magnetic Surveys
SECTION 5.8 • Gravity & Magnetics

Ground & Drone Magnetic Surveys

High-sensitivity Total Magnetic Intensity (TMI) and gradient surveys for mineral targeting

Overhauser magnetometer grids measuring Total Magnetic Intensity (TMI), Analytic Signal (ASA), and Reduced-to-Pole (RTP) to identify structural trends and ore bodies.

Depth: Surface to 2,000m+
Turnaround: 1-3 Weeks
Compliance: GSI NGPM Specifications
METHODOLOGY & SCIENCE

Overview & Scientific Principle

Magnetic surveys exploit variations in the Earth's geomagnetic field caused by the magnetic susceptibility of subsurface rocks and minerals. SPIPL has executed thousands of line-kilometers of high-sensitivity ground magnetics across India and overseas concessions, delivering pristine Total Magnetic Intensity (TMI) datasets that highlight lithological contacts, fault splays, and magnetic ore bodies.

Physical Principle:

Rocks containing ferromagnetic minerals (primarily magnetite, ilmenite, and pyrrhotite) become magnetized in the Earth's ambient field. Overhauser magnetometers measure the absolute scalar magnetic field with $0.01 \ \text{nT}$ sensitivity, while base stations monitor diurnal variations for micro-magnetic precision.

PRACTICAL APPLICATIONS

Where & When to Apply This Capability

Our clients deploy Ground & Drone Magnetic Surveys across various stages of civil engineering, mineral exploration, and environmental projects.

Banded Iron Formation (BIF) and massive magnetite orebody exploration
Kimberlite pipe, carbonatite, and lamprophyre intrusion detection
Basalt flows, dolerite dyke swarms, and fault structural tracing
Base metal sulfide deposits associated with pyrrhotite mineralization
Archaeological feature and buried unexploded ordnance (UXO) detection
EXECUTION RIGOR

Step-by-Step Technical Workflow

QA/QC Supervised
1

Base Station Deployment

Positioning a stationary Overhauser magnetometer in a magnetically quiet zone to log diurnal solar magnetic fluctuations every 3 seconds.

2

Walking Magnetometer Traverses

Walking planned grid lines with backpack-mounted sensors recording continuous magnetic readings and differential GPS coordinates.

3

Diurnal Correction & IGRF Removal

Synchronizing roving and base datasets to subtract diurnal drift and removing the International Geomagnetic Reference Field (IGRF).

4

Derivative & RTP Transformations

Applying 2D Fast Fourier Transforms (FFT) to compute Reduced-to-Pole (RTP), Analytic Signal, and tilt derivatives.

5

Structural & Orebody Interpretation

Tracing magnetic lineaments, calculating source depth via Euler deconvolution, and pinpointing exploratory borehole targets.

INSTRUMENTATION

Equipment Deployed

Calibrated, in-house industry-standard instruments operated by SPIPL senior geoscientists:

  • GEM Systems GSM-19T Overhauser Walking Magnetometers (0.01 nT sensitivity, 0.5 sec sampling)
  • Dedicated continuously logging base station magnetometers with GPS time sync
  • Non-magnetic carbon-fiber sensor poles and ergonomic field harnesses
  • Geosoft Oasis Montaj MAGMAP 2D frequency domain filtering software
  • UBC-GIF MAG3D mathematical inversion and voxel susceptibility modeling
OUTPUT & REPORTING

Client Deliverables Package

Upon survey completion, clients receive complete engineering documentation:

  • Diurnally-corrected Total Magnetic Intensity (TMI) contour and shade relief maps
  • Reduced-to-Pole (RTP) anomaly sheets centering dipole anomalies over their source bodies
  • Analytic Signal (ASA) and First Vertical Derivative (1VD) boundary enhancement maps
  • Apparent magnetic susceptibility cross-sections and 3D inversion volumes
  • Detailed structural interpretation overlays detailing inferred faults, folds, and dykes
Format: PDF, DWG/DXF, ESRI Shapefiles, SEG-2/DAT
TECHNICAL FAQS

Frequently Asked Technical Questions

Why is Reduced-to-Pole (RTP) processing necessary?

Except at the geomagnetic poles, the Earth's magnetic field is inclined, causing magnetic anomalies to appear as asymmetrical dipoles displaced from the actual center of the body. RTP transformation mathematically shifts anomalies so they sit directly vertically above the causative magnetic source.

What is the daily production capacity of a ground walking magnetic crew?

In accessible undulating terrain, a single walking magnetometer crew routinely logs 15 to 25 line-kilometers per day with continuous sub-second sampling.

CROSS-DISCIPLINARY SYNERGY

Frequently Paired Capabilities

Clients typically combine Ground & Drone Magnetic Surveys with these complementary methods to eliminate ambiguity:

Browse All 16 Domains
Gravity Surveys & Micro-Gravimetry
Section 5.7
Gravity & Magnetics

Gravity Surveys & Micro-Gravimetry

Detecting subtle subsurface density contrasts using Scintrex micro-gal gravimeters for sedimentary basin modeling, heavy mineral deposits, and regional tectonics.

Explore Service 50m to 5,000m+
Geological & Geophysical Surveys
Section 5.1
Integrated Exploration

Geological & Geophysical Surveys

Integrated field investigations combining geological outcrop mapping with targeted geophysics for unambiguous subsurface stratigraphy and hazard mapping.

Explore Service 10m to 1,500m
Mineral Exploration
Section 5.2
Mineral & Drilling

Mineral Exploration

Targeting mineralized zones and base metals with integrated potential field, electrical, and diamond core drilling programs across India and international concessions.

Explore Service 50m to 1,000m+