Electrical Resistivity Tomography (ERT)
SECTION 5.5 • Electrical & EM

Electrical Resistivity Tomography (ERT)

2D and 3D subsurface resistivity imaging for groundwater, faults, and void detection

Multi-electrode 2D/3D resistivity inversion mapping groundwater aquifers, lithological interfaces, fracture zones, karst cavities, and saline intrusion.

Depth: 10m to 200m+
Turnaround: 3-7 Days
Compliance: ASTM D6431
METHODOLOGY & SCIENCE

Overview & Scientific Principle

Electrical Resistivity Tomography (ERT) provides continuous, high-definition 2D and 3D cross-sections of subsurface apparent resistivity. Using computer-controlled multi-electrode switching arrays, ERT maps water saturation, clay distribution, fracture zones, cavities, and salinity contrasts with exceptional clarity.

Physical Principle:

Direct electrical current ($I$) is injected into the ground through a pair of electrodes, while resulting potential differences ($\Delta V$) are measured across another pair. Automated switching sequences test hundreds of electrode combinations across Wenner, Schlumberger, or Dipole-Dipole configurations, and the apparent resistivity data is inverted into true subsurface resistivity.

PRACTICAL APPLICATIONS

Where & When to Apply This Capability

Our clients deploy Electrical Resistivity Tomography (ERT) across various stages of civil engineering, mineral exploration, and environmental projects.

Groundwater exploration, deep aquifer boundary mapping, and drilling spot selection
Karst cavity, sinkhole, and subsurface void detection beneath foundations
Fault, shear zone, and structural fracture tracing in dam abutments
Saline water intrusion monitoring in coastal agricultural zones
Landfill leachate plume tracking and environmental contaminant mapping
EXECUTION RIGOR

Step-by-Step Technical Workflow

QA/QC Supervised
1

Array Design & Profile Staking

Selecting electrode spacing (1m to 10m) based on target depth vs. resolution, and staking profiles with GPS coordinates.

2

Electrode Planting & Contact Resistance Check

Driving stainless steel electrodes into the ground and running an automated test to ensure contact resistance $<2$ kOhm across all nodes.

3

Automated High-Speed Acquisition

Multi-channel acquisition cycling through hundreds of Wenner-Schlumberger or Dipole-Dipole measurement quadrupoles.

4

Smoothness-Constrained 2D/3D Inversion

Applying smoothness-constrained Gauss-Newton least-squares inversion with topographic correction to eliminate surface artifacts.

5

Hydrogeological & Geotechnical Interpretation

Correlating low resistivity zones ($<20 \ \Omega \cdot \text{m}$) with clays or saline water, and moderate values ($30-150 \ \Omega \cdot \text{m}$) with fresh water-bearing aquifers.

INSTRUMENTATION

Equipment Deployed

Calibrated, in-house industry-standard instruments operated by SPIPL senior geoscientists:

  • AGI SuperSting R8 multi-channel automated resistivity meter (8 simultaneous channels)
  • IRIS Syscal Pro multi-electrode resistivity system with 72-120 electrode lines
  • Stainless steel electrode stakes and low-resistance multi-core multicore cables
  • RES2DINV and RES3DINV robust non-linear inversion software suites
  • Automated contact-resistance diagnostic verification consoles
OUTPUT & REPORTING

Client Deliverables Package

Upon survey completion, clients receive complete engineering documentation:

  • Continuous high-resolution 2D Electrical Resistivity Tomograms (Ohm-m)
  • 3D resistivity depth slices and isometric fence diagrams
  • Lithological and hydrogeological interpretation cross-sections
  • Precise borehole / tubewell drilling location coordinates and anticipated water yields
  • Fully archived inverted XYZ dataset ready for GIS and CAD loading
Format: PDF, DWG/DXF, ESRI Shapefiles, SEG-2/DAT
TECHNICAL FAQS

Frequently Asked Technical Questions

Can ERT detect water directly?

ERT detects electrical resistivity contrasts. Water-bearing sands, gravels, or fractured rock zones exhibit substantially lower resistivity than surrounding dry dense rock, allowing hydrogeologists to accurately identify productive aquifer zones.

How deep can ERT reach?

Depth of investigation is roughly 20% of total spread length. With an 800m spread of electrodes, target depths up to 150-180 meters are reliably mapped.

CROSS-DISCIPLINARY SYNERGY

Frequently Paired Capabilities

Clients typically combine Electrical Resistivity Tomography (ERT) with these complementary methods to eliminate ambiguity:

Browse All 16 Domains
Ground Penetrating Radar (GPR)
Section 5.6
Electrical & EM

Ground Penetrating Radar (GPR)

High-frequency non-destructive electromagnetic radar profiling for underground utility mapping, road pavement layers, concrete rebar scanning, and shallow voids.

Geological & Geophysical Surveys
Section 5.1
Integrated Exploration

Geological & Geophysical Surveys

Integrated field investigations combining geological outcrop mapping with targeted geophysics for unambiguous subsurface stratigraphy and hazard mapping.

Explore Service 10m to 1,500m
Mineral Exploration
Section 5.2
Mineral & Drilling

Mineral Exploration

Targeting mineralized zones and base metals with integrated potential field, electrical, and diamond core drilling programs across India and international concessions.

Explore Service 50m to 1,000m+